Subject | Unit | Technical parameter | |
---|---|---|---|
Power supply | Voltage/Phase/Frequency | 380V/3P/50Hz | |
Refrigerant | R22 or R404A | ||
Capacity | Kg/day | 10000 | |
Cooling way | Water cooling | ||
Temperature | Ambient temperature | ℃ | 35 |
Waterinlet temperature | ℃ | 20 | |
Operating power | Cooling water pump | Kw | 1.1 |
Warm water pump | Kw | 0.75 | |
Ice cutter | Kw | 1.1 | |
Cooling tower fan | Kw | 1.1 | |
Cooling water pump | Kw | 2.2 | |
Total running power | Kw | 39.07 | |
Installment power | Kw | 48 | |
Compressor | Manufacturer | Bitzer | |
Refrigeration capacity | Kw | 71 | |
Operating power | Kw | 32.82 | |
Compressor COP/EER | Kw/kw | 2.16 | |
Horse power | Hp | 25×2sets | |
Type of compressor | Semi-hermetic screw | ||
Dimension | Size of machine unit | (L×W×H)(mm) | 1600×1200×1800 |
Number of evaporator | 1PC | ||
Size of evaporator | (L×W×H)(mm) | 2200×1700×2200 | |
Size of ice outlet | (L×W)(mm) | 1500×300 | |
Size of cooling tower | (O.D.×H)(mm) | Ф2000×2410 | |
Size of water feeding pipe of cooling tower | 3/4" | ||
Size of cooling water pipes | 2-1/2" | ||
Size of water feeding pipe | 3/4" | ||
Operating weight | Unit | Kg | 1150 |
Evaporator | Kg | 1460 | |
Cooling tower | Kg | 670 | |
Water supply pressure requirement | Bar | 1 |